The Product contains a built in thermal protector. When a motor overheats for any reason, the thermal protector is opened and the motor stops.
When the motor temperature drops, the thermal protector closes and the motor restarts. Be sure to turn the motor off before inspection.
Gearmotor Torque Table
The permissible torque is 200 Kg.cm.
50 Hz
Unit : kg.cm
RPM
500
416
300
250
200
166
120
100
83
60
50
41
30
25
20
16
15
12.5
10
8.3
Gear Ratio
3
3.6
5
6
7.5
9
12.5
15
18
25
30
36
50
60
75
90
100
120
150
180
Output Torque
7.3
8.7
12
15
18
22
30
36
44
55
66
79
99
118
145
177
195
200
200
200
60 Hz
Unit : kg.cm
RPM
600
500
360
300
240
200
144
120
100
72
60
50
36
30
24
20
18
15
12
10
Gear Ratio
3
3.6
5
6
7.5
9
12.5
15
18
25
30
36
50
60
75
90
100
120
150
180
Output Torque
6.3
7.5
11
13
16
19
26
32
38
47
57
68
86
102
121
140
180
200
200
200
The Gearheads are sold seperately. A Coloured background indicates gear shaft rotation in the same direction; a White background indicates rotation in the opposite direction as the motor shaft.
The Speed is calculated by dividing the motor's synchronous speed ( 50 Hz: 1500RPM, 60 Hz: 1800RPM ) by the gear ratio. The actual Speed is 2~20 % less than the displayed value, depending on the size of the load.
Characteristics, specifications and dimensions are subject to change without notice.
Make the connections as shown to rotate the motor in clockwise direction
To change the direction, flip SW to CCW
Short Black wires and connect as shown to rotate the motor in clockwise direction
To change the direction, flip SW to CCW
Red wires are for running winding & Black wires are for starting winding
To change the direction, interchange Black wires or Red wires
Wiring Diagram for Three Phase Motors
To change the direction, interchange any two wires between U, V & W For 415 Volt supply, wires are Red coloured
For 230 Volt supply, wires are White coloured
To change the direction, interchange any two wires between U, V & W
For 415 Volt supply, wires are connected as shown. Short White, Blank & Blue wire and then insulate properly
To change the direction, interchange any two wires between U, V & W
For 230 Volt 3 ph supply, wires are connected as shown
Change the direction of the motor only after it stops rotating. If the attempt is made during rotation, motor may ignore the reversing command or change the direction after some time.